DLMS/COSEM Driver

dc3-driver-dlms brings DLMS/COSEM metering devices into IoT DC3—targeting meters such as energy meters, it periodically reads COSEM object attributes addressed by OBIS codes.

DLMS/COSEM (Device Language Message Specification / Companion Specification for Energy Metering) is the international standard protocol (IEC 62056) for utility metering of electricity, water, gas, and heat. Each readable quantity in the device (e.g. active energy, voltage, clock) is modeled as a COSEM object, uniquely identified by an OBIS code (such as 1.0.1.8.0.255), and each object has several numbered attributes, where attribute 2 is usually the "present value". This driver uses the Gurux DLMS library to build and decode DLMS frames, acting as a client over TCP or serial to connect to the meter and read attribute values by the OBIS code configured on each Point.

Use cases: connecting meter-reading systems to electricity/water/gas meters, or energy-management platforms collecting metering data.

  • Driver name / code: DLMS/COSEM Driver / DlmsDriver
  • Type: DRIVER_CLIENT (actively connects to the meter)

Skeleton implementation for now

This driver is currently a template skeleton: the Gurux client can generate DLMS frames, but the transport send/receive is not yet implemented—in the current implementation read() / write() throw directly (a read failure throws ReadPointException, a write failure throws WritePointException), so the SDK records the failure and applies connection backoff rather than returning a fabricated value or write success; health() only checks whether a client object is cached (no real connectivity probe). Treat it as a starting point for onboarding a new meter, not a production-ready driver. The attribute tables and schedules below are taken from the real config and are safe to fill in, but the actual read behavior is still to be completed.

Driver configuration (device-level driver-attribute)

When onboarding a DLMS/COSEM device, fill these attributes on the Device:

AttributecodeTypeDefaultDescription
Transport TypetransportTypeSTRINGTCPTransport type (TCP, SERIAL)
HosthostSTRINGlocalhostRemote device address (TCP mode)
PortportINT4059Remote device port (TCP mode)
Serial PortserialPortSTRING/dev/ttyUSB0Serial port path (SERIAL mode)
Baud RatebaudRateINT9600Baud rate (SERIAL mode)
Client AddressclientAddressINT16DLMS client address (public client=16)
Server AddressserverAddressINT1DLMS server address
AuthenticationauthenticationSTRINGNONEAuthentication method (NONE, LOW, HIGH)
PasswordpasswordSTRING(empty)Authentication password

TCP or SERIAL, pick one

With transportType=TCP, only host / port are used; with transportType=SERIAL, only serialPort / baudRate are used. The other group is ignored under the current transport and need not be removed. clientAddress / serverAddress / authentication / password apply to both modes.

Point configuration (point-attribute)

Fill these on each Point to locate the COSEM object to read by OBIS code:

AttributecodeTypeDefaultDescription
Object TypeobjectTypeSTRINGREGISTERDLMS object type (REGISTER, CLOCK, DATA, etc.)
Logical NamelogicalNameSTRING(empty)Object logical name / OBIS code (e.g. 1.0.1.8.0.255)
Attribute IDattributeIdINT2Attribute ID (2=Present Value)

The OBIS code locates "which quantity to read"

logicalName is a 6-part OBIS code uniquely identifying one metering quantity in the meter—for example 1.0.1.8.0.255 is "total active energy". attributeId=2 reads the object's "present value" attribute. The Point's data type (Point's pointTypeFlag) must match the actual type of the object attribute.

DLMS/COSEM is read-only metering semantics, and this driver provides no write commands—command-attribute is empty in application.yml, so there is no write-command configuration table.

Acquisition and health

  • Acquisition cycle: default read cron 0/30 * * * * ? (one read round every 30 seconds); plus a custom scheduled task cron 0/5 * * * * ? (every 5 seconds)—the current schedule() is a no-op, so this task runs no logic for now.
  • Health / online: device health check default cron 0/15 * * * * ?, lease timeout 45 seconds—see Device for the online-status mechanism.

Minimal onboarding example

Onboard one electricity meter at IP 192.168.1.20:4059 and read total active energy:

  1. Create a Device with DLMS/COSEM Driver, filling driver attributes transportType=TCP, host=192.168.1.20, port=4059, clientAddress=16, serverAddress=1, authentication=NONE.
  2. Add an energy Point to the Profile bound to the device (pointTypeFlag=DOUBLE, READ_ONLY), filling point attributes objectType=REGISTER, logicalName=1.0.1.8.0.255, attributeId=2.
  3. Start the driver; a read round triggers within 30 seconds—but the current read() throws ReadPointException directly, so the SDK records a read failure and backs off, and no value appears in PointValue for now; a real value is only collected once the transport layer is completed.

Common pitfalls

Host/Port must match the transport type

host / port only take effect under transportType=TCP. If you set transportType to SERIAL but only filled in host, the driver follows the serial branch and looks for serialPort, failing to reach the meter. When changing the transport type, remember to fill in the corresponding group of attributes.

clientAddress defaults to the public client

clientAddress=16 is the DLMS "public client", which most meters allow to read basic metering quantities without authentication. To read protected objects, switch to a higher-privilege client address and raise authentication to LOW / HIGH with a password.